Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Trauma ; (12): 348-353, 2019.
Article in Chinese | WPRIM | ID: wpr-745062

ABSTRACT

Objective To investigate the effect of axial load test in Taylor spatial frame treatment of external fixation for tibia and fibula fractures.Methods A retrospective case-control study was conducted to analyze the clinical data of 36 patients with open fracture of tibia and fibula admitted to Tianjin Hospital from March 2015 to June 2017.There were 22 males and 14 females,aged 21-71 years[(46.1±14.2)years].All patients received Taylor spatial frame external fixation for tibia and fibula fracture within 1 week after injury.After operation,18 patients received axial load test(experiment group),and the other 18 did not(control group).When the value of axial load test was less than 5% in experiment group,the Taylor spatial frame was removed.The control group used traditional method to remove the Taylor spatial frame.Comparisons were made between the two groups in terms of treatment duration,total cost,re-fracture after Taylor spatial frame removal and incidence of stent-tract infection.Results All patients were followed up for 3-14 months with an average of 8.6 months.Compared with control group,the treatment duration[(36.17±11 .44)weeks vs.(44.50±9.16)weeks]and total cost[(93.7±7.9)thousand yuan vs.(120.1±10.6)thousand yuan]of experiment group were significantly lower(P<0.05).In the experiment group,there was 0 patient with re-fracture and two patients with stent-tract infection,with the complication incidence of 11%,while there were two patients with re-fracture and three patients with stent-tract infection,with the complication incidence of 28% in the control group(P>0.05).Conclusions After Taylor spatial frame external fixation for tibia and fibula fractures,regular axial load test can safely and timely guide the removal of Taylor spatial frame.It can reduce the treatment duration and cost compared with the traditional removal method,being safe and reliable.

2.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 144-148, 2019.
Article in Chinese | WPRIM | ID: wpr-856603

ABSTRACT

Objective: To explore the effectiveness of Taylor spatial frame (TSF) in the treatment of tibiofibular fractures and computer-assisted closed reduction. Methods: The clinical data of 30 cases of tibiofibular fractures with soft tissue injury treated with TSF between January 2015 and September 2017 was retrospectively analyzed. According to different reduction methods, the patients were divided into control group (15 cases, open reduction in TSF external fixation) and trial group (15 cases, closed reduction in 1-3 days after TSF external fixation). There was no significant difference in the general data such as gender, age, affected side, cause of injury, AO classification of fracture, time from injury to operation between the two groups ( P>0.05). The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator were recorded and compared between the two groups. At 3 months after removal of external fixator, the limb function was evaluated according to Johner-Wruhs criteria for evaluating the final effect of tibial shaft fracture treatment. Results: Both groups were followed up 9-16 months, with an average of 14 months. The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator in the trial group were significantly shorter than those in the control group ( P<0.05). There were 2 cases of superficial infection of the external fixation (1 case in each group), 1 case of incision infection (control group), 1 case of delayed fracture healing (control group), 2 cases of traumatic arthritis (1 case in each group); no significant difference was found in the incidence of complications between the two groups ( χ2=0.370, P=0.543). The wounds of soft tissue defect healed by the first intension in both groups. At 3 months after removal of the external fixator, the limb function results in the trial group were excellent in 3 cases, good in 9 cases, fair in 2 cases, and poor in 1 case, and the excellent and good rate was 80.0%; in the control group, the results were excellent in 3 cases, good in 8 cases, fair in 3 cases, and poor in 1 case, and the excellent and good rate was 73.3%. There was no significant difference in incidence of complication between the two groups ( χ2=0.917, P=0.821). Conclusion: Compared with intraoperative open reduction, postoperative computer-aided closed reduction can shorten the operation time, reduce the intraoperative blood loss, reduce the risk of long-term operation, avoid to destroy the blood supply of fracture end, shorten the healing time of fracture and the wearing time of stent, and alleviate the pain of patients after TSF treatment of tibiofibular fracture.

3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 931-935, 2017.
Article in Chinese | WPRIM | ID: wpr-856870

ABSTRACT

Objective: To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation.

SELECTION OF CITATIONS
SEARCH DETAIL